• Before you install the appliance, fit it with
the applicable hob from the table.
Type Maximum power
PEM 6000 E 6000 W
PES 6000 E 5800 W
PES 6060 E 7600 W
594
7
20
570
590
540
560
550 min
600
560-570
80÷100
A
B
Electrical installation
Warning! Only a qualified and
competent person must do the
electrical installation.
The manufacturer is not responsible if
you do not follow safety precautions
from chapter "Safety".
This appliance is supplied without a main
plug and a main cable.
The cable
Cable types applicable for installation or re-
placement: H07 RN-F, H05 RN-F, H05
RRF, H05 VV-F, H05 V2V2-F (T90), H05
BB-F.
For the section of the cable refer to the total
power (on the rating plate) and to the table:
Total power Section of the cable
maximum 1380 W 3 x 0,75 mm²